Seljakotile paigaldatav tuulega töötav tulekustuti
6MF-23-51
Võtke meiega ühendust, et osta
Toote spetsifikatsioonid
▲1. Test Basis: GB/T10280-2008 Portable Wind-Powered Fire Extinguishers for Forestry Machinery;
2. Effective Wind-Powered Fire Extinguishing Distance ≥2.31m;
3. Airflow at outlet ≥0.5m³/s;
4. Continuous operation reliability: Operates continuously for 5 hours at rated speed without failure. Speed drop rate after 5 hours is 3.3% of rated speed. Functions normally after restart.
▲5. Safety protection (no oil leakage, no electrical leakage): Complies with GB/T10280-2008;
▲6. Thermal Protection: Complies with GB/T10280-2008;
7. Ambient Temperature Start-up: ≤5s
▲8. Overspeed Test: Complies with GB/T10280-2008;
▲9. Impeller Static Balancing Test: Complies with GB/T10280-2008;
▲10. Overall assembly quality: Correct and complete assembly; moving parts shall operate smoothly without interference or obstruction.
▲11. Tilt test: At rated speed, tilt forward, backward, left, and right 45° once each; remain in each position for no less than 10 seconds while maintaining normal operation.
▲12. Engine power and rated speed: Compliant with GB/T10280-2008; Rated power: 4.0 kW; Rated speed: 7200 r/min; Engine type: Single-cylinder air-cooled two-stroke;
▲13. Continuous operating time per fueling: ≥69 min;
▲14. Ear-level noise: ≤102.7 dB(A);
15. Hand-held vibration: ≤1.9 m/s²;
16. Curb weight: ≤14.7 kg; Net weight: ≤10.74 kg;
17. Fuel tank capacity: 2.65 L;
18. Appearance quality: Plastic parts shall have smooth surfaces free of cracks, sink marks, or other defects. Stamped parts shall be intact, free of cracks and burrs. Castings shall be free of defects such as shrinkage cavities, porosity, and deformation. Welded joints shall be smooth, free of burn-through, cracks, and incomplete welds. Plated parts shall have uniform coating, secure adhesion, and a smooth surface.
▲19. Instruction manual: Compliant with GB/T10280-2008;
▲20. Marking and Packaging: Compliant with GB/T10280-2008;
21. Fire-Resistant End Duct Connection Method:
Metal ducts: Stainless steel or aluminum alloy ducts equipped with anti-static devices internally. End ducts shall be adjustable with telescopic capability.
(Products marked with ▲ require supporting test reports bearing CMA and CNAS certifications issued by provincial-level or higher testing institutions.)